Thermo Finnigan Power Supply Module for LCQ Duo
Thermo Finnigan 97000-98041 Electron Multiplier High Voltage Power Supply (8 kV)
The Thermo Finnigan 97000-98041 is a high-precision, regulated high-voltage power supply module engineered for the LCQ Duo, LCQ Deca, and TSQ mass spectrometry platforms. This module provides the stable 8 kV (100 µA) output necessary to bias the electron multiplier, ensuring the efficient amplification of secondary electrons generated during the detection process. Designed for extreme stability and low ripple, the 97000-98041 is critical for maintaining the high signal-to-noise ratio and wide dynamic range required for sensitive LC/MS/MS analytical sequences.
Technical Performance and Design
-
Regulated 8 kV Output: Delivers a consistent high-voltage bias (up to 8,000V @ 100 µA) to the electron multiplier, enabling the high-gain amplification required for trace-level analyte detection.
-
Low-Noise Circuitry: Engineered to provide ultra-clean voltage output, minimizing electronic noise and interference that could otherwise compromise the integrity of the mass spectral baseline.
-
Continuous Analytical Workload: Built with high-grade industrial components designed to maintain steady output during long-duration runs and high-throughput automated laboratory workflows.
-
Modular Installation: Features secure, high-voltage internal connections and a compact form factor designed for direct integration into the LCQ Duo's high-voltage electronics bay.
Product Specifications
-
Catalog Number: 97000-98041
-
Description: Electron Multiplier HV Power Supply (Dynode HV Support)
-
Output Rating: 8 kV @ 100 µA
-
Manufacturer: Thermo Finnigan (Thermo Fisher Scientific)
-
System Compatibility: Thermo Finnigan LCQ Duo, LCQ Deca, LCQ Deca Plus, and TSQ Series Mass Spectrometers.
Key Benefits & Maintenance Applications
-
Signal Amplification Recovery: The primary replacement component for systems failing "Multiplier Gain" calibrations or showing zero ion counts despite successful ion trapping.
-
Diagnostic Troubleshooting: Essential for resolving "High Voltage Fault" errors specifically related to the detector bias electronics.
-
Spectral Integrity: Corrects issues of "ghosting" or erratic signal intensities caused by fluctuating bias voltages at the electron multiplier stage.
-
OEM Integration: Direct-fit replacement module designed to work in tandem with the 97000-98042 Conversion Dynode supply for a complete high-voltage detection overhaul.