{"product_id":"thermo-scientific-59396-1-zymark-caliper-waste-segregation-valve-kit-for-tpw-ii","title":"Thermo Scientific Zymark Caliper Waste Segregation Valve Kit for TPW II Total of 2 Kits","description":"\u003ch3\u003eThermo Scientific Zymark Caliper Waste Segregation Valve Kit for TPW II (59396\/1) – Lot of 2 Kits\u003c\/h3\u003e\n\u003cp\u003eThe Thermo Scientific Zymark Caliper Waste Segregation Valve Kit (59396\/1) is an engineered fluidic sub-assembly designed for integration into the Tablet Processing Workstation II (TPW II) automated sample preparation system. This specialized valve assembly automates the fluidic separation and directional routing of hazardous chemical waste, aqueous extraction buffers, organic solvents, and rinse effluents generated during automated tablet content uniformity and assay testing. Constructed with high-purity, chemically inert PTFE and fluoropolymer fluid contact pathways, the valve prevents cross-contamination between consecutive analytical runs while ensuring safe disposal into designated waste containers. Supplied as a lot of 2 complete valve kits, this hardware package includes precision solenoid valve modules, tubing harnesses, and fluidic connectors required to maintain optimal automated operation in high-throughput pharmaceutical quality control and analytical development laboratories.\u003c\/p\u003e\n\u003ch3\u003eTechnical Performance \u0026amp; Structural Attributes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChemically Inert Fluid Contact Surfaces: Precision-machined PTFE and fluoropolymer valve body components resist degradation from strong acids, alkalis, and aggressive organic solvents.\u003c\/li\u003e\n\u003cli\u003eAutomated Waste Stream Routing: Microprocessor-controlled solenoid operation directs aqueous, organic, and highly concentrated sample waste into designated disposal channels.\u003c\/li\u003e\n\u003cli\u003eZero Dead-Volume Architecture: Low internal volume minimizes fluid retention, preventing sample carryover and eliminating cross-contamination during continuous assay sequences.\u003c\/li\u003e\n\u003cli\u003eHigh Reliability Solenoid Drive: Engineered for high-cycle automated switching to match the continuous operation demands of high-throughput pharmaceutical workstations.\u003c\/li\u003e\n\u003cli\u003eDirect Plug-and-Play Integration: Custom-configured mounting brackets and pre-terminated electrical\/fluidic connections ensure seamless installation into standard TPW II chassis layouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCatalog \/ Part Number: 59396\/1 (also referenced under Zymark \/ Caliper product lines)\u003c\/li\u003e\n\u003cli\u003ePrimary Manufacturer: Thermo Scientific \/ Zymark (Caliper Life Sciences \/ PerkinElmer)\u003c\/li\u003e\n\u003cli\u003eEquipment Category: Automated Sample Preparation Hardware \/ Waste Segregation Fluidics\u003c\/li\u003e\n\u003cli\u003eHost Instrument Compatibility: TPW II (Tablet Processing Workstation II)\u003c\/li\u003e\n\u003cli\u003eWetted Materials: PTFE (Polytetrafluoroethylene) \/ FFKM \/ Inert Fluoropolymer Matrix\u003c\/li\u003e\n\u003cli\u003eValve Mechanism: High-Precision Multi-Port Solenoid Directional Valve Assembly\u003c\/li\u003e\n\u003cli\u003eControl Signal Interface: Integrated Multi-Pin Solenoid Power and Logic Cable Assembly\u003c\/li\u003e\n\u003cli\u003eMaximum Fluid Operating Pressure: 30 psi (2.0 bar)\u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range: 15 degrees C to 40 degrees C\u003c\/li\u003e\n\u003cli\u003ePackaging Configuration: Lot of 2 Complete Waste Segregation Valve Kits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Benefits \u0026amp; Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated Pharmaceutical QC Testing: Streamlines waste stream management during high-volume tablet assay and content uniformity processing on the TPW II platform.\u003c\/li\u003e\n\u003cli\u003eEnvironmental \u0026amp; Safety Compliance: Automatically isolates halogenated organic solvents from aqueous waste streams to simplify lab waste handling and safety compliance.\u003c\/li\u003e\n\u003cli\u003eWorkstation Maintenance \u0026amp; Upgrades: Restores precise fluid routing accuracy and prevents leakages in legacy automated sample preparation workstations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003csmall\u003eAll product names, logos, and brands are property of their respective owners. Thermo Scientific, Zymark, Caliper, and TPW II are registered trademarks of Thermo Fisher Scientific Inc. and its subsidiaries.\u003c\/small\u003e\u003c\/p\u003e","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":68060857139452,"sku":"SB-00348","price":72.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0627\/8463\/5132\/files\/IMG_6184_Shopify1024.jpg?v=1793718502","url":"https:\/\/lifesciencestrading.com\/es\/products\/thermo-scientific-59396-1-zymark-caliper-waste-segregation-valve-kit-for-tpw-ii","provider":"Life Sciences Trading","version":"1.0","type":"link"}