{"product_id":"artel-mvs-microtiter-plate-reader-and-mvs-shaker-plate","title":"Artel MVS Microtiter Plate Reader and MVS Shaker Plate","description":"\u003ch3\u003eArtel ELx800NB MVS Microtiter Plate Reader and MVS Microplate Shaker System\u003c\/h3\u003e\n\u003cp\u003eThe Artel ELx800NB MVS Microtiter Plate Reader and MVS Shaker System is a specialized, high-precision optical absorbance detection and fluid mixing platform designed for automated liquid handler volume verification and microplate-based assay reading. Originally manufactured by BioTek Instruments and customized for the Artel Multichannel Verification System (MVS), the ELx800NB reader utilizes precision interference filters and high-stability optics to measure dual-wavelength absorbance across standard 96-well and 384-well microplates. The accompanying MVS Microplate Shaker provides controlled, uniform orbital agitation, ensuring complete liquid homogenization and flat meniscus formation required for standardized optical pathlength measurement. Together, this system provides essential hardware for verifying liquid delivery accuracy, precision, and volumetric performance in automated bio-dispensing workflows.\u003c\/p\u003e\n\u003ch3\u003eTechnical Performance \u0026amp; Structural Attributes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-Wavelength Absorbance Optics: High-resolution optical channels with interference filter wheel selection enable precise ratiometric absorbance measurements critical for dye-based volume determination.\u003c\/li\u003e\n\u003cli\u003eStandard \u0026amp; High-Density Plate Support: Reads standard 96-well flat-bottom microplates and 384-well microplates with excellent well-to-well repeatability and minimal stray light crosstalk.\u003c\/li\u003e\n\u003cli\u003eUniform Orbital Microplate Agitation: The dedicated MVS Shaker delivers controlled orbital mixing parameters to eliminate fluid stratification and bubble formation prior to optical measurement.\u003c\/li\u003e\n\u003cli\u003eOn-Board Microprocessor \u0026amp; PC Data Interface: Supports direct RS-232 \/ serial communication with Artel MVS System Software for automated calculation of volumetric dispense accuracy and coefficient of variation (%CV).\u003c\/li\u003e\n\u003cli\u003eRugged Optical Engine Architecture: Built with long-life tungsten-halogen light sources and silicon photodiode detectors for long-term baseline stability and low drift.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSystem Component Models: Artel ELx800NB Plate Reader (BioTek ELx800NB Platform) \u0026amp; Artel MVS Shaker Plate Assembly\u003c\/li\u003e\n\u003cli\u003ePrimary Manufacturers: Artel \/ BioTek Instruments (Agilent Technologies)\u003c\/li\u003e\n\u003cli\u003eDetection Mode: Absorbance \/ Optical Density (OD)\u003c\/li\u003e\n\u003cli\u003eMicroplate Formats: 96-well and 384-well Microplates\u003c\/li\u003e\n\u003cli\u003eWavelength Range: 400 nm to 750 nm (Configured with MVS-specific filter sets)\u003c\/li\u003e\n\u003cli\u003eDynamic Range: 0.000 to 3.000 OD\u003c\/li\u003e\n\u003cli\u003ePhotometric Accuracy: ± 1.0% or ± 0.010 OD\u003c\/li\u003e\n\u003cli\u003eShaker Motion Profile: High-Frequency Controlled Orbital Agitation\u003c\/li\u003e\n\u003cli\u003eCommunication Interface: Serial RS-232 Port for Automated MVS Software Integration\u003c\/li\u003e\n\u003cli\u003eElectrical Requirements: 100–240V AC, 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Benefits \u0026amp; Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated Liquid Handler Calibration (MVS): Works as the optical core of the Artel MVS system to verify dispense accuracy and precision of multi-channel pipettors and robotic liquid handlers.\u003c\/li\u003e\n\u003cli\u003eQuality Control \u0026amp; Regulatory Compliance: Provides traceable volumetric measurement supporting ISO 17025, CLIA, CAP, and cGMP laboratory requirements.\u003c\/li\u003e\n\u003cli\u003eHomogeneous Colorimetric Assays: Combined shaker and reader setup is ideal for endpoint colorimetric assays, ELISA reactions, and protein quantification assays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsed, tested to be in great working condition.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003csmall\u003eAll product names, logos, and brands are property of their respective owners. Artel, MVS, ELx800, and BioTek are registered trademarks of Artel, Inc. and BioTek Instruments \/ Agilent Technologies, Inc.\u003c\/small\u003e\u003c\/p\u003e","brand":"Artel","offers":[{"title":"Default Title","offer_id":67694655045884,"sku":"11000","price":1425.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0627\/8463\/5132\/files\/artel-mvs-microtiter-plate-reader-and-mvs-shaker-plate-microplate-readers-artel-116522.jpg?v=1791920466","url":"https:\/\/lifesciencestrading.com\/products\/artel-mvs-microtiter-plate-reader-and-mvs-shaker-plate","provider":"Life Sciences Trading","version":"1.0","type":"link"}