{"product_id":"cytiva-filter-heater-compatible-with-xuri-cell-expansion-system-w25","title":"Cytiva Filter Heater Compatible with Xuri Cell Expansion System W25","description":"\u003ch3\u003eCytiva 29-0444-71 Filter Heater for Xuri™ Cell Expansion System W25\u003c\/h3\u003e\n\u003cp\u003eThe Cytiva 29-0444-71 is a dedicated thermal management accessory engineered for use with the Xuri™ Cell Expansion System W25 and ReadyToProcess WAVE™ 25 rocking bioreactors. This filter heater is designed to be placed around the exhaust (outlet) air filter of a single-use Cellbag™ bioreactor. By maintaining the filter at an elevated temperature, it effectively prevents the condensation of water vapor from the humidified headspace of the culture. This is a mission-critical safety component in cell therapy manufacturing, as it ensures the exhaust path remains unobstructed, preventing pressure buildup and maintaining the precise gas exchange parameters required for high-density T-cell expansion.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Performance and Design\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eCondensation Prevention:\u003c\/b\u003e Specifically designed to keep the hydrophobic vent filter dry, ensuring that CO2 and O2 exchange remain consistent throughout the duration of the cell expansion process.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cp style=\"margin: 0;\"\u003e\u003cb\u003ePlug-and-Play Integration:\u003c\/b\u003e Features a specialized connector that interfaces directly with the Xuri™ W25 CBCU (Cellbag Control Unit) or the WAVE™ 25 Rocker, allowing the UNICORN™ software to monitor and control the heater's status.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eDurable \u0026amp; Cleanable Design:\u003c\/b\u003e Constructed with a robust, chemically resistant outer shell that can be easily wiped down with standard laboratory disinfectants (such as 70% IPA) to maintain cleanroom compliance.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eSelf-Regulating Safety:\u003c\/b\u003e Engineered to provide consistent localized heating (typically 32VDC \/ 4W) without risking damage to the single-use filter media or the plastic housing of the Cellbag.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eCatalog Number:\u003c\/b\u003e 29-0444-71 (Code No: 29036750)\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eCompatibility:\u003c\/b\u003e Cytiva Xuri™ W25, ReadyToProcess WAVE™ 25\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cp style=\"margin: 0;\"\u003e\u003cb\u003ePower Requirements:\u003c\/b\u003e 32V DC, 4W\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eApplication:\u003c\/b\u003e Exhaust Air Filter Heating\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eMaterial:\u003c\/b\u003e High-performance polymer \/ Heat-conductive core\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eConnector Type:\u003c\/b\u003e Specific 4-pin\/6-pin circular connector for W25\/WAVE 25 series.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Benefits \u0026amp; Applications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eClosed-System Integrity:\u003c\/b\u003e Essential for maintaining the functionally closed environment of the Xuri™ system, especially during long-term perfusion cultures where humidity levels are high.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eT-Cell \u0026amp; Immunotherapy Manufacturing:\u003c\/b\u003e Standard equipment in CAR-T and TCR process development, where any interruption in gas flow can impact cell viability and phenotype.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eRisk Mitigation:\u003c\/b\u003e Prevents the \"filter blinding\" phenomenon, which is the leading cause of pressure-related bag ruptures in rocking bioreactor systems.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eRegulated Environments:\u003c\/b\u003e Manufactured to the high quality standards required for cGMP manufacturing, ensuring consistent performance across clinical and commercial batches.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003cp style=\"margin: 0; font-size: 0.8em;\"\u003e\u003ci\u003eAll product names, logos, and brands are property of their respective owners. \u003c\/i\u003e\u003c\/p\u003e","brand":"Cytiva","offers":[{"title":"Default Title","offer_id":44498178310396,"sku":"4331","price":135.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0627\/8463\/5132\/files\/cytiva-filter-heater-compatible-with-xuri-cell-expansion-system-w25-lab-equipmentother-lab-equipment-cytiva-498905.jpg?v=1764388751","url":"https:\/\/lifesciencestrading.com\/products\/cytiva-filter-heater-compatible-with-xuri-cell-expansion-system-w25","provider":"Life Sciences Trading","version":"1.0","type":"link"}