{"product_id":"harvard-apparatus-syringe-infusion-pump-11","title":"Harvard Apparatus Syringe Infusion Pump 11","description":"\u003cp\u003e\u003cspan class=\"citation-245 interactive-span-hovered\"\u003eThe \u003c\/span\u003e\u003cspan class=\"citation-245 interactive-span-hovered\"\u003eHarvard Apparatus 55-1199\u003c\/span\u003e\u003cspan class=\"citation-245 interactive-span-hovered\"\u003e is a classic, high-precision single-syringe infusion pump from the legendary \u003c\/span\u003e\u003cspan class=\"citation-245 interactive-span-hovered\"\u003ePump 11 series\u003c\/span\u003e\u003cspan class=\"citation-245 citation-end-245 interactive-span-hovered\"\u003e.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e Known for its \"legendary reliability,\" this microprocessor-controlled unit is designed for applications requiring consistent, low-to-moderate back pressure and smooth fluid delivery, such as mass spec calibration, microfluidics, and drug studies.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"1\"\u003eCore Functionality \u0026amp; Performance\u003c\/h3\u003e\n\u003cul data-path-to-node=\"2\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,0,0\" id=\"p-rc_6dea5a8c963c97c4-167\"\u003e\u003cspan class=\"citation-244\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-244\"\u003eInfusion-Only Operation:\u003c\/span\u003e\u003cspan class=\"citation-244 citation-end-244\"\u003e The 55-1199 model is an \"Infusion Only\" pump, meaning it moves in one direction to dispense fluid.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,1,0\"\u003eSmooth Flow: It utilizes a micro-stepping drive to eliminate the \"pulsing\" common in lesser pumps, ensuring a near-continuous flow even at microliter rates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,2,0\" id=\"p-rc_6dea5a8c963c97c4-168\"\u003e\u003cspan class=\"citation-243\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-243\"\u003eCalibration:\u003c\/span\u003e\u003cspan class=\"citation-243\"\u003e Features \u003c\/span\u003e\u003cspan class=\"citation-243\"\u003eautomatic calibration\u003c\/span\u003e\u003cspan class=\"citation-243 citation-end-243\"\u003e.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-242 citation-end-242\"\u003eYou simply enter the syringe's inside diameter (ID), and the microprocessor calculates the correct motor speed to achieve your target flow rate.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"citation-244 citation-end-244\"\u003eNon-Volatile Memory:\u003cspan class=\"citation-241 citation-end-241\"\u003e The pump \"remembers\" your last settings (syringe size and flow rate) even after being powered off, which is essential for repetitive lab protocols.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable data-path-to-node=\"4\" style=\"width: 100%; height: 176.344px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.3359%; height: 19.5938px;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.807%; height: 19.5938px;\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.3359%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"4,1,0,0\"\u003e\u003cb data-path-to-node=\"4,1,0,0\" data-index-in-node=\"0\"\u003eSyringe Compatibility\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.807%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"4,1,1,0\"\u003e1 syringe: 10 µL to 60 mL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.3359%; height: 39.1875px;\"\u003e\u003cspan data-path-to-node=\"4,2,0,0\"\u003e\u003cb data-path-to-node=\"4,2,0,0\" data-index-in-node=\"0\"\u003eFlow Rate Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.807%; height: 39.1875px;\"\u003e\u003cspan data-path-to-node=\"4,2,1,0\"\u003e0.0014 µl\/hr (with 0.5 µl syringe) to 26.55 ml\/min (with 60 ml syringe)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.3359%; height: 39.1875px;\"\u003e\u003cspan data-path-to-node=\"4,3,0,0\"\u003e\u003cb data-path-to-node=\"4,3,0,0\" data-index-in-node=\"0\"\u003eAccuracy \/ Reproducibility\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.807%; height: 39.1875px;\"\u003e\u003cspan data-path-to-node=\"4,3,1,0\"\u003e±0.5% \/ ±0.1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.3359%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"4,4,0,0\"\u003e\u003cb data-path-to-node=\"4,4,0,0\" data-index-in-node=\"0\"\u003eLinear Force\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.807%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"4,4,1,0\"\u003eAverage of 17 lbs (8 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.3359%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"4,5,0,0\"\u003e\u003cb data-path-to-node=\"4,5,0,0\" data-index-in-node=\"0\"\u003eDisplay\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.807%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"4,5,1,0\"\u003e2-line, 16-character vacuum fluorescent display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.3359%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"4,6,0,0\"\u003e\u003cb data-path-to-node=\"4,6,0,0\" data-index-in-node=\"0\"\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.807%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"4,6,1,0\"\u003e9″ W x 4.5″ D x 4.5″ H (22.9 x 11.4 x 11.4 cm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eUsed, tested to be in great working condition.\u003c\/p\u003e","brand":"Harvard Apparatus","offers":[{"title":"Default Title","offer_id":49019974123772,"sku":"10681","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0627\/8463\/5132\/files\/IMG_3085_Shopify1024.jpg?v=1777044947","url":"https:\/\/lifesciencestrading.com\/products\/harvard-apparatus-syringe-infusion-pump-11","provider":"Life Sciences Trading","version":"1.0","type":"link"}