{"product_id":"miltenyi-biotec-column-block-multi-24","title":"Miltenyi Biotec Column Block Multi-24 7 Column Blocks","description":"\u003ch3\u003eMiltenyi Biotec 130-095-691 Multi-24 Column Block (Individually Sealed)\u003c\/h3\u003e\n\u003cp\u003eThe Miltenyi Biotec 130-095-691 is a high-throughput magnetic cell separation consumable designed for use with the MultiMACS™ Cell24 Separator Plus and the fully automated MultiMACS™ X. This Multi-24 Column Block enables the parallel isolation of virtually any cell type from up to 24 samples simultaneously, providing significant time savings and experimental standardization. Each block consists of 24 individual MACS® columns integrated into a single unit, featuring a specialized ferromagnetic sphere matrix with a cell-friendly coating. This design induces a high-gradient magnetic field that gently retains magnetically labeled cells while allowing unlabeled fractions to flow through. Each column block is individually sealed and sterile-packed to ensure the highest integrity for cell culture, flow cytometry, and molecular analysis.\u003c\/p\u003e\n\u003ch3\u003eTechnical Performance and Design\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eParallel Processing Power:\u003c\/b\u003e Enables simultaneous positive selection or depletion of up to 24 samples, ensuring that all samples are processed under identical magnetic field conditions for superior reproducibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eHigh-Gradient MACS® Technology:\u003c\/b\u003e The matrix of ferromagnetic spheres amplifies the magnetic field of the MultiMACS™ instrument by 10,000-fold. This allows for the retention of cells even with minimal MicroBead labeling, leaving more epitopes free for subsequent antibody staining.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cb\u003e\"Flow-Stop\" Functionality:\u003c\/b\u003e The columns are engineered with a flow-stop feature, meaning they will not run dry even if left unattended, protecting cell viability and preventing air bubbles from entering the matrix.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eVersatile Sample Scaling:\u003c\/b\u003e While designed for 24 samples, the block can be used for fewer samples by using column blanks, or used to split one large-volume sample (like a Leukopak®) across multiple columns to maintain high purity and recovery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eCatalog Number:\u003c\/b\u003e 130-095-691 (8-Block Pack)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eCompatibility:\u003c\/b\u003e MultiMACS™ Cell24 Separator Plus, MultiMACS™ X\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eColumn Capacity:\u003c\/b\u003e 1x10⁸ magnetically labeled cells from up to 1x10⁹ total cells per single column.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eReservoir Volume:\u003c\/b\u003e 5.0 ml per column\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eVoid Volume:\u003c\/b\u003e 250 µl\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eSterility:\u003c\/b\u003e Sterile and Individually Sealed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cb\u003ePackaging:\u003c\/b\u003e Includes 8 Multi-24 Column Blocks and 8 sterile-packed 24-well Deep Well Plates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Benefits \u0026amp; Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eImmunology Research:\u003c\/b\u003e Ideal for the rapid isolation of T cells, B cells, or rare circulating tumor cells (CTCs) from multiple donors or experimental conditions in a single run.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eLarge Volume Processing:\u003c\/b\u003e Allows researchers to divide a single large sample, such as buffy coat or dissociated tissue, across 24 columns to prevent clogging and maximize purity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eGentle Elution:\u003c\/b\u003e When used with the MACS® Elution Station, the vacuum-driven pulse ensures gentle and simultaneous elution of all 24 samples, maintaining maximal cell viability for downstream culture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cb\u003eStandardized Workflows:\u003c\/b\u003e Eliminates the variability inherent in manual single-column separations, making it the preferred choice for labs performing high-volume screening or longitudinal studies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eExpiration: 09-Feb-2023.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Miltenyi Biotec","offers":[{"title":"Default Title","offer_id":44498165399804,"sku":"4291","price":282.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0627\/8463\/5132\/files\/miltenyi-biotec-column-block-multi-24-7-column-blocks-lab-equipmentother-lab-equipment-miltenyi-biotec-958919.jpg?v=1728764851","url":"https:\/\/lifesciencestrading.com\/products\/miltenyi-biotec-column-block-multi-24","provider":"Life Sciences Trading","version":"1.0","type":"link"}