{"product_id":"thermo-scientific-insulating-foam-ring-fits-model-g","title":"Thermo Scientific Insulating Foam Ring Fits Model G","description":"\u003ch3\u003eThermo Scientific Savant Vapor Trap Cover Insulating Foam Ring (145-6012-00)\u003c\/h3\u003e\n\u003cp\u003eThe Thermo Scientific 145-6012-00 (alternatively cataloged under Fisher Scientific as Part Number NC0980083) is an OEM replacement thermal component engineered for integrated vacuum concentrators and cold vapor traps. Constructed from a high-density, closed-cell insulation composite, this foam ring is custom-molded to fit the cover assembly of Model G glass condensation flasks (including GCF400 setups). By providing a strict thermal boundary layer, it prevents ambient heat exchange, accelerates vapor condensation cycles, and eliminates condensation sweating on external instrument housings during high-vacuum evaporative protocols.\u003c\/p\u003e\n\u003ch3\u003eTechnical Performance \u0026amp; Design\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThermal Boundary Optimization: Formulated from structural closed-cell insulation foam that isolates cold trap chambers from ambient room heat, maximizing the deposition efficiency of volatile solvents on cooling surfaces.\u003c\/li\u003e\n\u003cli\u003eAnti-Sweat Condensation Control: Prevents moisture from air humidity from liquefying on outer chamber components, shielding nearby electronics and vacuum manifolds from water pooling or chemical-mist contact.\u003c\/li\u003e\n\u003cli\u003eSnug-Fit Geometric Calibration: Designed specifically to slip over and seal against the perimeter of Model G collection lids, ensuring a zero-clearance friction seal without using volatile adhesive backings.\u003c\/li\u003e\n\u003cli\u003eChemical-Vapor Shielding: The robust poly-foam matrix resists surface degradation when exposed to common evaporated lab solvents, weak organic acid mists, and standard chemical cleaners.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number \/ Part No: 145-6012-00 (Factory Designation: RING, COVER INSUL FOAM FITS G)\u003c\/li\u003e\n\u003cli\u003eFisher Scientific Catalog Number: NC0980083\u003c\/li\u003e\n\u003cli\u003ePrimary Manufacturer: Thermo Fisher Scientific Inc.\u003c\/li\u003e\n\u003cli\u003eSystem Line Compatibility: Savant SpeedVac™ Integrated Vacuum Concentrator Systems (including SPD1030 and SPD2030 series) and standard standalone cold traps utilizing a Model G Glass Condensation Flask (GCF400 \/ GIT400).\u003c\/li\u003e\n\u003cli\u003eMaterial Composition: High-Density Closed-Cell Technical Elastomeric Foam\u003c\/li\u003e\n\u003cli\u003eColor Sizing: Matte Dark Gray \/ Charcoal Black\u003c\/li\u003e\n\u003cli\u003eSterility Status: Non-Sterile\u003c\/li\u003e\n\u003cli\u003ePackaging Configuration: Sold individually as 1 single replacement component per package unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Benefits \u0026amp; Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpeedVac Run Maintenance: Maintains the extreme low-temperature differentials necessary to condense and trap solvents rapidly, optimizing sample dryness times across concentration workflows.\u003c\/li\u003e\n\u003cli\u003eProtective Pump Shielding: Assists in maximizing the efficiency of the cold barrier to trap volatile vapors completely, preventing aggressive chemicals from migrating past the flask and degrading internal mechanical pump oil.\u003c\/li\u003e\n\u003cli\u003eDirect OEM Component Fitment: Serves as a direct drop-in part for worn, torn, or chemically degraded insulation covers, returning vacuum concentrator stations to factory-validated technical performance specifications.\u003c\/li\u003e\n\u003cli\u003eTool-Free Bench Installation: The pliable structure slips cleanly over the glass trap cover assembly manually, facilitating rapid maintenance cycles during scheduled lab equipment inspections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsed, in good condition.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003csmall\u003eThermo Scientific™, Savant™, and SpeedVac™ are registered trademarks of Thermo Fisher Scientific Inc. Part number 145-6012-00 represents the insulating ring specifically calibrated for Model G glass condensation lids. For smaller or alternative glass traps (such as the 4-liter GIT400 system components), alternative foam variants like the GTC400 assembly must be specified independently.\u003c\/small\u003e\u003c\/p\u003e","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":49202557354236,"sku":"10807","price":61.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0627\/8463\/5132\/files\/thermo-scientific-insulating-foam-ring-fits-model-g-other-healthcare-lab-dental-thermo-scientific-647908.jpg?v=1781545006","url":"https:\/\/lifesciencestrading.com\/zh\/products\/thermo-scientific-insulating-foam-ring-fits-model-g","provider":"Life Sciences Trading","version":"1.0","type":"link"}