{"product_id":"warner-instruments-stage-adapter-for-nikon-diaphot-108-dia-sa-nik","title":"Warner Instruments Stage Adapter for Nikon Diaphot 108 Dia. SA-NIK","description":"\u003cp\u003e\u003cspan class=\"citation-232\"\u003eThe \u003c\/span\u003e\u003cspan class=\"citation-232\"\u003eWarner Instruments 64-0291\u003c\/span\u003e\u003cspan class=\"citation-232\"\u003e (Model \u003c\/span\u003e\u003cspan class=\"citation-232\"\u003eSA-NIK\u003c\/span\u003e\u003cspan class=\"citation-232\"\u003e) is a specialized microscope stage adapter designed to integrate \u003c\/span\u003e\u003cspan class=\"citation-232\"\u003eSeries 20\u003c\/span\u003e\u003cspan class=\"citation-232\"\u003e imaging and recording chambers into the stages of \u003c\/span\u003e\u003cspan class=\"citation-232\"\u003eNikon Diaphot\u003c\/span\u003e\u003cspan class=\"citation-232 citation-end-232\"\u003e and related inverted microscope models.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e It serves as a thermal and mechanical interface, allowing for stable, high-precision microscopy during live-cell imaging or electrophysiology.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003eThe primary purpose of the SA-NIK is to bridge the gap between the microscope stage’s large circular cutout and the smaller footprint of a Warner Series 20 platform (such as the P-1, PM-1, or PH-1).\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003eMechanical Stability: It features two button clamps that securely lock the chamber platform into place, preventing any lateral movement during high-magnification imaging or perfusion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\" id=\"p-rc_1749c9ad10e96db1-157\"\u003e\u003cspan class=\"citation-231\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-231\"\u003eThermal Isolation:\u003c\/span\u003e\u003cspan class=\"citation-231\"\u003e Machined from \u003c\/span\u003e\u003cspan class=\"citation-231\"\u003ehigh-quality Delrin® (plastic)\u003c\/span\u003e\u003cspan class=\"citation-231 citation-end-231\"\u003e, the adapter acts as a thermal barrier.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e This is critical when using heated platforms; it prevents the heavy metal microscope stage from acting as a \"heat sink,\" which would otherwise make temperature regulation difficult and inefficient.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable data-path-to-node=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,0,0\"\u003e\u003cb data-path-to-node=\"5,1,0,0\" data-index-in-node=\"0\"\u003eModel Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,1,0\"\u003eSA-NIK\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,0,0\"\u003e\u003cb data-path-to-node=\"5,2,0,0\" data-index-in-node=\"0\"\u003eOrder Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,1,0\"\u003e64-0291\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,0,0\"\u003e\u003cb data-path-to-node=\"5,3,0,0\" data-index-in-node=\"0\"\u003eStage Cutout Diameter\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,1,0\"\u003e108 mm (10.8 cm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,0,0\"\u003e\u003cb data-path-to-node=\"5,4,0,0\" data-index-in-node=\"0\"\u003eMaterial\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,1,0\"\u003eBlack Delrin® (Acetal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,0,0\"\u003e\u003cb data-path-to-node=\"5,5,0,0\" data-index-in-node=\"0\"\u003eSeries Compatibility\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,1,0\"\u003eDesigned for all Warner Series 20 Platforms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,0,0\"\u003e\u003cb data-path-to-node=\"5,6,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,1,0\"\u003eLightweight for minimal stage load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Warner Instruments","offers":[{"title":"Default Title","offer_id":49013995897084,"sku":"10677","price":142.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0627\/8463\/5132\/files\/warner-instruments-stage-adapter-for-nikon-diaphot-108-dia-sa-nik-microscope-camera-lens-adapters-warner-instruments-916644.jpg?v=1778281284","url":"https:\/\/lifesciencestrading.com\/zh\/products\/warner-instruments-stage-adapter-for-nikon-diaphot-108-dia-sa-nik","provider":"Life Sciences Trading","version":"1.0","type":"link"}